General Description
MIL-STD-1275 Power Line Protection are unique, small dimension units that provide adequate protection against all over voltage transients (Surges and Spikes) phenomena of power lines, in ground mobile vehicles. It is designed for both floating and grounded to chassis input voltage. The small dimension enables PCB mounting for ease of usage. The product is also available in wire-lead termination for other installation options. The product contains reversed polarity protection and clamping
of high voltage input. The protection is against high (up to 100V@50ms) surges and spikes (± 250V@15mJ). This power line protection is the solution for equipment that
does not powered by PDSU product
Typical Specifications
Input Working Voltage:
12V to 33V
Input Transient Voltage:
+100V@50msec@0.5Ω source impedance ±250Vpk@50usec@15mj
Output Working Voltage:
VO=VIN - Dropout (11Vmin to 33Vmax)
Output Transient Working Voltage:
33V to 37V@50msec
Working Current:
20A max.
Input to Output Voltage Dropout:
1V@20A, 100mV@0.5A, 0.6V@12A,
Power Dissipation:
20W max@20A, 10W@10A
Transient Power Dissipation:
2000W@50msec
Shut Down:
“0” Enabled
Insulation (Only for floated configuration):
Input to Chassis:
1500Vdc@1sec
Output to Chassis:
1500Vdc@1sec
Quiescent Current:
20mA@ VIN=24V
Reverse Voltage Protection:
0 to (-36V)
Response Time:
ton=20msec@Vin=0V to VIN=24V
Dimensions:
half brick case (57.9mmX61.0mmX21.4mm)
Weight:
125gr
Environmental Conditions:
Operating Temperatures:
- 40°C to 71°C
Storage temperatures:
- 40°C to 71°C
Vibration:
Method 514.5, Proc I, Cat 20 Ground Vehicle.
Shock:
40g X 15ms Saw Tooth